DELPHYS MX (250-900 kVA)

img img

DELPHYS MX (250-900 kVA)

  • from 250 to 900 kVA
    the Mega Power protection up to 5.4 MVA

  • Data centres

  • Industry

  • Telecommunications

  • Processes

Lower Total Cost of Ownership


  • Minimized running costs, by:

  • - very high efficiency of up to 93.5% (VFI mode),

    - ‘Energy saver’ automatically adapts the number of running units to the real load,

    free-cooling compatible.

  • Reduced footprint.

  • Exceptional high power density (the most compact unit of its class): 900 kVA in less than 3.2 meters (width) per unit including the bypass.

  • PFC “clean input” rectifier (without filters) with a lasting high input power factor whatever the operating conditions.

  • Intelligent built-in battery monitoring system interacts with “charging mode” to prolong battery lifetime.

  • Leading power factor load compatible without derating.


High reliability and availability


  • Internal fault-tolerant architecture with internal redundancies and fan failure localisation.

  • Intelligent embedded battery monitoring with failed block localisation and preventative remote alarm.

  • Able to withstand an output short-circuit and overload.

  • Reliable and robust paralleling mode.

  • Multisystem automatic cross synchronisation (ACS) for an optimized use with STS.

  • Output isolation transformer to reduce the influence of N-GND (Neutral Line-to-Ground) voltage and load harmonic current on UPS inverter.


Flexible architecture


  • Parallel system with modular units.

  • Powerful central bypass for power extension or redundancy.

  • Tier 3 and Tier 4 compatible.

  • Designed for optimal use with STS in downstream network.


User-friendly operation


  • A control panel with graphic display for more ergonomic operation.

  • An array of “com-slot” plug-in communication interfaces, for upgrading your operating requirements.

  • Reduced MTTR thanks to extractible power bridges or fans on “cassette”.

  • Front accessibility for all components.


User-friendly operation


  • A control panel with graphic display for more ergonomic operation.

  • An array of “com-slot” plug-in communication interfaces, for upgrading your operating requirements evolution.


Simplified maintenance


  • Easy remote monitoring via web browser or via customer’s supervision systems (web, intranet, extranet…).

  • Very open connectivity (Modbus/Jbus, Jbus tunnelling, LAN).


Simplified maintenance


  • To fulfil the most demanding needs for power supply availability, flexibility and the installation to be upgraded.

  • Modular parallel up to 6 units, development without constraint.

  • Double bypass, for easier operation.

  • Twin channel architecture with Static Transfer Systems.