DELPHYS MX (250-900 kVA)
DELPHYS MX (250-900 kVA)
-
from 250 to 900 kVA
the Mega Power protection up to 5.4 MVA
Data centres
Industry
Telecommunications
Processes
Lower Total Cost of Ownership
Minimized running costs, by:
Reduced footprint.
Exceptional high power density (the most compact unit of its class): 900 kVA in less than 3.2 meters (width) per unit including the bypass.
PFC “clean input” rectifier (without filters) with a lasting high input power factor whatever the operating conditions.
Intelligent built-in battery monitoring system interacts with “charging mode” to prolong battery lifetime.
Leading power factor load compatible without derating.
- very high efficiency of up to 93.5% (VFI mode),
- ‘Energy saver’ automatically adapts the number of running units to the real load,
free-cooling compatible.
High reliability and availability
Internal fault-tolerant architecture with internal redundancies and fan failure localisation.
Intelligent embedded battery monitoring with failed block localisation and preventative remote alarm.
Able to withstand an output short-circuit and overload.
Reliable and robust paralleling mode.
Multisystem automatic cross synchronisation (ACS) for an optimized use with STS.
Output isolation transformer to reduce the influence of N-GND (Neutral Line-to-Ground) voltage and load harmonic current on UPS inverter.
Flexible architecture
Parallel system with modular units.
Powerful central bypass for power extension or redundancy.
Tier 3 and Tier 4 compatible.
Designed for optimal use with STS in downstream network.
User-friendly operation
A control panel with graphic display for more ergonomic operation.
An array of “com-slot” plug-in communication interfaces, for upgrading your operating requirements.
Reduced MTTR thanks to extractible power bridges or fans on “cassette”.
Front accessibility for all components.
User-friendly operation
A control panel with graphic display for more ergonomic operation.
An array of “com-slot” plug-in communication interfaces, for upgrading your operating requirements evolution.
Simplified maintenance
Easy remote monitoring via web browser or via customer’s supervision systems (web, intranet, extranet…).
Very open connectivity (Modbus/Jbus, Jbus tunnelling, LAN).
Simplified maintenance
To fulfil the most demanding needs for power supply availability, flexibility and the installation to be upgraded.
Modular parallel up to 6 units, development without constraint.
Double bypass, for easier operation.
Twin channel architecture with Static Transfer Systems.